25 North Colonnade, Canary Wharf – Pressurisation System

Image courtesy of https://www.flickr.com/photos/mattbuck007/ Delta carried out smoke ventilation maintenance, upgrades, and repairs at a busy distribution centre.

Delta Smoke Control delivered a mechanical pressurisation system at 25 North Colonnade, Canary Wharf, to safeguard stair cores and lobbies in the high-rise office building.

Challenge

Delivering a solution suitable for high-rise office building.

Location

25 North Colonnade, Canary Wharf, London

Project

A mechanical pressurisation system at 25 North Colonnade, Canary Wharf, to safeguard stair cores and lobbies in the high-rise office building. Incorporating Kingspan Light & Air Estra ventilators for controlled air release, the system maintains safe pressure levels during a fire and integrates seamlessly with the building’s management and fire alarm systems

Goal

Providing a compliant and dependable smoke control solution, to safeguard stair cores and lobbies in the high-rise office building.

25 North Colonnade, Canary Wharf

At 25 North Colonnade in London’s Canary Wharf, Delta Smoke Control was engaged to support the upgrade of the building’s life‑safety systems with a focus on protected escape routes. In a high‑rise office environment, maintaining clear, smoke‑free stair cores and lobbies is critical, so the chosen strategy centred on a mechanical pressurisation system.

Delta designed and commissioned a solution utilising Kingspan Light & Air Estra ventilators to provide air release paths from the office spaces, ensuring that the spaces served are not overly pressurised, allowing the system to maintain smoke fire conditions within the firefighting core.

 The system is configured to maintain positive pressure differentials during a fire event, controlling airflow across open doors to resist smoke ingress while keeping door forces within acceptable limits. Our team coordinated closely with the wider project stakeholders to integrate controls, pressure monitoring and override facilities into the building management and fire alarm systems. The result is a reliable, code‑compliant smoke control arrangement that enhances occupant safety and demonstrates the value of combining specialist pressurisation design with high‑quality equipment.

If you have any questions, please email us at:

sales@deltasmokecontrol.co.uk

Call us on+44 (0)23 9286 3888

or fill out our contact form.

Our Customers

We’ve worked with a wide range of clients over the years – many of them subcontractors on large development projects – delivering for some of the biggest and most successful global companies.

IQL logo
sky logo
newcastle uni logo
jag logo
land rover
cheltenham
airforce